All systems are operational

Past Incidents

23rd September 2024

Ticket#INC-xxxxx | September 22, 2024 | JMT & SCT SITE | Planned | Service Provider Network Maintenance - JMT & SCT Site, scheduled 8 months ago

• Event : Service Provider Essential Maintenance

• Schedule : September 22, 2024 (Sunday) | 1:00 AM (PHT) – 5:00 AM (PHT)

• Activity Details : Dear Team,

One of our Site to Datacenter circuit service provider will be conducting a scheduled network maintenance to perform Service Migration.

During the maintenance, the affected circuit will be unavailable, however due to the configuration of our network having backup circuits, we expect only partial impact on internet and network connectivity. This may manifest as slow application performance, while remote desktop sessions and VOIP calls may experience intermittent disconnects within a 4-5 minute timeframe while automatic failovers/failback activate.

• Service Impact : Partial to no impact on internet and network connectivity – JMT & SCT Site

16th September 2024

No incidents reported

15th September 2024

Ticket#INC-79986| September 14, 2024 | TIM Data Center | Data Center Annual Preventive Maintenance - September 14, 2024, scheduled 9 months ago

• Event : Data Center Preventive Maintenance

• Schedule : September 14, 2024 | 08:00 AM PHT – September 15, 2024 | 05:05 AM PHT September 21, 2024 | 08:00 AM PHT – September 22, 2024 | 05:55 AM PHT

• Activity Details : Hi Team,

We would like to inform you that one of our Data Center will be conducting its Annual Preventive Maintenance on the following dates:

• September 14, 2024, 08:00 AM to September 15, 2024, 05:05 AM: PDU 14 for Rack L-06 (TIMC-01F-CP-R1) • September 21, 2024, 08:00 AM to September 22, 2024, 05:55 AM: PDU 11 for Rack L-06 (TIMC-01F-CP-R2)

During this maintenance, the affected PDU on the rack will be unavailable. However, due to the NCP network's hardware redundancy configuration, we expect only partial or no impact on services.

• Service Impact :Partial to no impact on network connectivity

Ticket#NC-79983 | September 14 2024 | TIM Data Center | Planned | Data Center Annual Preventive Maintenance - September 14, 2024, scheduled 9 months ago

• Event : Data Center Preventive Maintenance

• Schedule : September 14, 2024 | 08:00 AM PHT – September 15, 2024 | 05:05 AM PHT September 21, 2024 | 08:00 AM PHT – September 22, 2024 | 05:55 AM PHT

• Activity Details : Hi Team,

We would like to inform that one of our Data Center will be conducting the Annual Preventive Maintenance activity on the following dates:

September 14, 2024, 08:00 AM to September 15, 2024, 05:05 AM September 21, 2024, 08:00 AM to September 22, 2024, 05:55 AM

Please note that no service impact is expected during this maintenance. However, should you have any concerns or require further information, feel free to reach out.

• Service Impact : No Impact to Network and Internet Connectivity

14th September 2024

Network and Internet Ticket#xxxx| September 14, 2024| The Ignacia Place (TIP)| Site to Datacenter Circuit Interruption – RESTORED

• Event : Unplanned Service Provider Network Interruption at The Ignacia Place (TIP)

• Incident: September 14, 2024 (Saturday) | 10:52 AM – 8:36 PM | RESTORED

Hi Team,

One of our Site to Datacenter Circuit in TIP went down but was already restored since 8:36PM. We already coordinated this to our service provider for their further investigation.

Due to our network’s configuration, only a partial impact on internet and network connectivity was expected , as we have another circuit uplink available that serves as a backup.

Additional information and a Root Cause Analysis (RCA) of the incident will be shared once available.

• Service Impact : Partial impact on network and internet connectivity for both wired and wireless connection - TIP

13th September 2024

No incidents reported

12th September 2024

Power Ticket#xxxx | September 12, 2024 | NTB | Unplanned | Power Interruption at Neutrinus Building Pilando Center (NTB - Baguio)

• Event : Power Service Interruption at NTB

• Incident Date/Time :September 12, 2024 (Thursday) | 9:03 PM

• Activity Details : We are currently experiencing unscheduled power interruption at the Neutrinos Building Baguio Site.

As of 9:03PM, the building’s electricity is being suppled by a generator set. We will continue to monitor the situation and provide updates, as necessary.

There is no expected impact on the network and internet connectivity due to the availability of generator set and Uninterruptible Power Supplies (UPS) serving as backup power for our network devices. However, devices without battery support, such as desktops and other equipment, may experience fluctuations.

• Service Impact :NTB Building Main Power Supply

11th September 2024

No incidents reported

10th September 2024

No incidents reported

9th September 2024

No incidents reported

8th September 2024

No incidents reported

7th September 2024

No incidents reported